SEOUL METROPOLITAN GOVERNMENT ORDINANCE ON STANDARDS FOR CONSTRUCTION OF UNDERGROUND PUBLIC PEDESTRIAN FACILITIES
Enactment No. 5325, Jul. 30, 2012 | Amendment of Other Laws No. 6386, Jan. 05, 2017 |
---|---|
Article 1 (Purposes)
The purpose of this Ordinance is to provide for matters delegated by the Rules on Determination, Structure and Standards for Construction of Underground Public Pedestrian Facilities and matters necessary for the enforcement thereof.
|
Same as left |
Article 2 (Definitions)
The definitions of terms used in this Ordinance shall be as follows:
|
Same as left |
Article 3 (Structure and Standards for Installation of Staircases in Underground Pedestrian Passage)
(1) Where staircases are installed on the ground of a underground pedestrian passage pursuant to the proviso to Article 5 (3) of the Rules on Determination, Structure and Standards for Construction of Underground Public Pedestrian Facilities (hereinafter referred to as the "Rules"), staircases installed between entrances and exits of the underground passage shall not be installed at more than two places lest the staircases should interfere with refuge and safety of the users.
|
Same as left |
Article 4 (Two- or More Story Structure and Standards for Construction of Underground Pedestrian Passage)
(1) In principle, the structure of a underground pedestrian passage that may be constructed pursuant to the proviso to Article 5 (5) of the Rules shall be limited to two underground levels for lighting, ventilation and refuge and safety of the users: Provided, That a person who has the authority to give approval approves because the underground pedestrial passage has been planned so that it may not interfere with lighting, ventilation and refuge and safety of the users, it may be constructed in structure of below three underground levels following deliberations by the Urban Planning Committee of Seoul Metropolitan Government.
|
Same as left |
Article 5 (Structure and Standards for Construction of Underground Plaza)
(1) Where the structure of a underground pedestrian passage is two or more stories pursuant to Article 4, the underground plaza shall be constructed with the size of at least 10 percent of the size of the underground shopping mall on each floor.
|
Same as left |
Article 6 (Standards for Construction of Underground Shopping Mall)
(1) Where the structure of a underground pedestrian passage is two or more stories pursuant to Article 4, the total sizes of stores set up in the underground shopping mall on each floor shall not be more than the total sizes of the size of the underground pedestrian passage and the size of the underground plaza on each floor.
|
Same as left |
Article 7 (Structure and Standards for Construction of Entrances and Exits of Underground Passage)
(1) Where the structure of a underground pedestrian passage is two or more stories pursuant to Article 4, the inside distance between entrances and exits of the underground pedestrian passage shall be within 90 meters.
|
Same as left |
Article 8 (Structure and Standards for Construction of Passages Connecting Underground Floors)
(1) Where a passage connecting underground floors is constructed in a contrary direction to a underground pedestrian passage pursuant to Article 9 (2) of the Rules, the minimum width of the passage connecting underground floors shall be at least 4.5 meters.
|
Same as left |
Article 9 (Structure and Standards for Construction of Skylight)
(1) Where the structure of a underground pedestrian passage is two or more stories pursuant to Article 4, a skylight necessary for lighting, ventilation and smoke emission shall be constructed with the size of at least two percent of the size of a underground shopping mall in an open type at the same location of each floor of the underground public pedestrian facilities: Provided, That where it is difficult or unreasonable to construct a skylight, etc. below two underground levels, it may be constructed by being added to the size of a skylight in one underground level following deliberations by the Urban Planning Committee of Seoul Metropolitan Government.
|
Same as left |
Article 10 (Types and Standards for Installation of Ancillary Facilities)
Where the structure of a underground pedestrian passage is two or more stories, types and standards for construction of ancillary facilities that should be constructed in underground public pedestrian facilities shall be as follows:
|
Same as left |
ADDENDA <Ordinance No. 5325, Jul. 30, 2012> |
Same as left |